Nir3 flame detector pdf files

Fsl100 series flame detectors fsl100 flame detector types fsl100uv, fsl100uvir and fsl100 ir3. They can operate on a conventional 2wire 1428 vdc fire systems or 420ma process control systems. The threaded portions of the detector are flame paths. The uvir radiation flame detector is a dual spectrum optical detector sensitive. A flame detector is a sensor designed to detect and respond to the presence of a flame or fire, allowing flame detection. This version of uvir flame detector is electronic devices designed to sense the occurrence of fire and flames and subsequently activate an alarm or an extinguishing system directly or through a control circuit. The stateoftheart multispectral infrared technology of esp safetys model ipesir3 flame detector affords the highest level of sensitivity in detecting. Th e detector can be supplie d with an optional built. Testing the cf series detector the fixed temperature only detector. Fire sentry flame detectors flame detectors flame and.

The detector has three sensors which respond to different ir wavelengths to discriminate between flames and spurious sources of radiation. The fv40 series includes the latest technology for the best detection and resistance to false alarms, while keeping budgets in mind. It is optimized for detection of hydrogen, ethanol, methanol and methane natural gas fires and like the other detectors in its family, it responds to type a, b and c flaming fires. Choice of red or white housings range 110 ft 35 m ir3, 25 m80 ft uv, uvir alarming within 10 seconds to a 1 ft20. Fmx5000 ir flame detectors meet the highest sensitivity class 1 in accordance with en 5410. Detection point of about 60 degrees, particularly sensitive to the flame spectrum.

Ir3 flame detector s advanced microprocessor based technology ensures rapid flame recognition and alarm. Reports for detector layouts and zone coverage can be exported to microsoft excel and pdf files to incorporate into a final report. Fds301 flame detector fds301 safety and technical manual 5 ref. These flame detectors give excellent immunity to false flame sources both indoors or out. The co 2 peak emits intense radiation in the spectral band between 4. Pdf flame detection using pir sensors researchgate. Extended line monitoring is necessary for en 54 compliant operation.

The 3600lb uses a combination of ultraviolet uv and infraredir sensor technology. This type of detector is fitted with the help of a flange. Firespecific signals are digitally processed by the microcontroller preventing false alarms e. A flame detector s most basic performance criteria are detection. Description flame detection sensor module is sensitive to the flame, but also can detect ordinary light. A flame detector is a sensor designed to detect and respond to the presence of a flame or fire. The 3600m uses infrared ir technology, a reliable design that provides early warning of flaming fires and immunity to false alarms from ir sources such as sunlight and ir projectors.

The flame detector testers are suitable to test uv, uvir, uvir2, ir, ir2, ir3, hydrogen ir3, multispectrum ir flame detectors. Ir infrared flame detection sensor module detect fire. With inbuilt automatic test and test lamps available to cover all models, reliability is ensured. Detect3d capabilities software for fire and gas mapping. The flame detectors are used with honeywell flame safeguard controls to provide flame supervision for gas, oil, or combination gasoil burners. We got the assignment to built a detector there could detect a 10kr coin at 5cm. The fv400 flamevision detectors use triple ir solar blind sensing technology and flame detection. Fire protection systemsfire protection systems univario flame detector fmx5000 uv the watchful eye the fmx5000 uv flame detector evaluates the uv range of the optical spectrum. Flame detector is designed to protect areas where open fires may be expected and detects almost all flames, including hydrocarbon fires with 4. Phoenix triple ir flame detector bcr002000030 product data sheet june 2012 pms uncoated pms coated cmyk grey black pms cmyk greyscale black very serious risks to human life, productivity. For instance, safety systems builds automatic self check asc directly into each optical flame detector. View and download lst 16589 specification sheet online. Standard features include two independently adjustable flame relays that can be selected to operate from the uv sensor, the ir sensor, or both sensors, 21 choices of modulation frequency, adjustable sensor gain, adjustable flame relay onoff thresholds, two 420 ma analog signal strength outputs one for fr1 and one for fr2, fault relay, four selectable programmable files e. Flame detectors working principle instrumentation tools.

The newest optoelectronic flame detector for a wide range of light industrial fire detection from honeywell analytics. These selfchecks are programmed to occur periodically. Whatever the reason, an automatic fire detection and alarm system generally provides a network of manual call points, heat and smoke detectors, and alarm warning devices over the area covered. The 4040i is the most durable and weather resistant flame detector currently on the market. It detects the ultraviolet and infrared spectral regions of the flame to produce a system which is highly immune to false alarms caused by lightning, arcwelding, hot objects, and other sources of radiation. C7915a infrared flame detector application the c7915a flame detector includes a lead sulfide photocell that is sensitive to the infrared radiation emitted by the combustion of fuels such as natural gas, oil, and coal. Showing objects most relevant to your location first. Ultraviolet uv detectors they have the ability to detect fires and explosions in about 34 ms. Ipesir3 flame detector operating manual page 1 of 32 1. Sharpeyetm ir3 flame detector manual tm 2020i, rev. The uv detector can accurately distinguish the type of flame the moment it spots a. Single ir flame detector hydrocarbonbased flame detection. Particularly suitable for combination or dualfuel applications. Figure 2 spectral response of uv and ir detectors uvir flame detector fl3110 the model fl3110 is a discriminating uvir detector, which makes use of an ultraviolet radiation sensitive phototube in addition to an infrared detector see figure 2.

No part of the hardware, software or documentation may be reproduced, transmitted. In this paper, a flame detection system based on a pyroelectric or passive infrared pir sensor is described. Flame detectors have a 3d cone of vision ranging from 90 degrees for the 3600 series to 120 degrees for the 3100, 3200 and 3300 series flame detector. Responses to a detected flame depend on the installation, but can include.

Notifiers fire sentry ss2, ss3, ss4, fs20x and fs24x is a family of multispectrum, electrooptical digital fire and flame detectors representing leading edge uv, ir and vis technology for a wide range. Notifiers third edition of the fire and gas detection catalogue contains innovative and intelligent products for a broad range of applications in the life safety domain. Powerful algorithms running on a digital signal processor dsp are tuned to. C7027a, c7035, c7044a minipeeper ultraviolet flame detectors the c7027a, c703sa and c7044a detect the ultraviolet radiation emitted by combustion flames. Fire alarm systems 016519 flame detector flameproof ex d, ir3 016519 flame detector flameproof ex d, ir3. Elimination of false alarms false alarms from detectors used for industrial applications can cost productivity in down time. It may seem simple and straight forward to design a sensitive optical flame detector by utilizing ultraviolet uv, infrared ir or a combination of uvir sensors. Salwico offers a wide range of flame detectors to provide protection. Triple ir ir3 flame detector user guide 8200 market blvd, chanhassen, mn 55317, usa phone. Honeywell fsl100ir3 technical handbook pdf download. The ir3 flame detector is designed for harsh environments in indoor applications. Although beam smoke detectors are not suited for all applications, they may be the detector.

The detector is engineered to respond to the nominal 4. All of these characteristics also have benign sources other than fire, such as heat from steam pipes, particle matter from aerosols, and light from the sun. Fortunately, flame detector manufacturers have employed the latest in circuit technology to incorporate selfdiagnostics. Devices using open flame are prohibited from testing heat detectors. This operating manual specifies performance characteristics of the flame detector hereinafter ipesir3, which are guaranteed by the manufacturer jsc electronstandartpribor. The uvir flame detector senses radiant energy in the short wave sections of both. Detection point of about 60 degrees, particularly sensitive to the flame. The 4040i, a multi spectrum based on three ir bands ir3, detects fuel and gas fires at long distances with the highest immunity to false alarms. Flame detector, ir3 flame detectors automatic fire. Flame detector is sensitive to flickering, low frequency 1 15hz.

Depending on model, this includes a variety of gas and fuel fires including those. Relay contacts are also available for fire and fault. A guide groove in the securing flange and a cam on the detector clamp ensure vibrationfree mounting and make certain that the photo resistive flame detector is always correctly sited towards the flame. This provides a reliable and cost effective solution in standard flame detection applications especially where there is a single hazard in the field of view. This version of ir3 flame detector is electronic devices designed to sense the occurrence of fire and flames and subsequently activate an alarm or an extinguishing system directly or through a control circuit. The spectrex sharpeye optical flame detector described in this document is the property of rosemount. Responses to a detected flame depend on the installation, but can include sounding an alarm, deactivating a fuel line such as a propane or a natural gas line, and activating a fire suppression system. Sharpeyetm uvir flame detector manual tm2020lb rev e, august 2004 1 1. In fact, the flame detector will detect fires at greater distances, but the flame size at such distances needs to be proportionally greater in order to be sure of reliable detection. The flame detector is designed for use where open flaming fires may be expected. Most fire detection technology focuses on detecting heat, smoke particle matter or flame light the three major characteristics of fire. Triple ir ir3 flame detector superior performance, reliability and immunity to false alarms the new 4040i, a multi spectrum based on three ir bands ir3, detects fuel and gas fires at long distances. Double circuit normally open contacts fire detection devices.

Flame detector technical information series 072000. The ir3 radiation flame detector is a dual spectrum optical detector sensitive. Arduino flame sensor interfacing to build a fire alarm system. The triple infrared ir3 flame detector is designed to protect areas where open fires may be expected. View and download honeywell fsl100ir3 technical handbook online. They have internal selftest sources that check the detectors operation when remotely instructed. This is especially noted for automated systems and processes. Salwico flame detectors salwico produces various flame detectors, which are a vital part of the salwico fire detection systems. The flame detection system can be used for fire detection in large rooms. The result is a unique flame detector, which does not produ ce false alarms and provides at the same time detection over greatly increased distances.

Ss4auv the ss4auv represents the leading edge technology uv optical flame detectors. Metal detector is a device that can detect metal, the basics can make a sound when it is near some metal, and the more advanced can tell what kin of metal and how deep it is down, they are using different detecting principles. Flamevision flame detectors flamevision fv300 flamevision fv300 uses infrared array based sensing technology to provide the ultimate programmable flame detector. The device cannot be used with an fpc500 conventional fire panel.

C7061 af dynamic self check ultraviolet flame detector application the c7061a is a dynamic selfchecking flame detector for sensing the ultraviolet radiation generated by the combustion of gas, oil, or other fuels. Sharpeyetm ir3 flame detector manual tm 2020si, rev. The fv300 flamevision detectors offer a major improvement in both flame detection ca pability a nd immunity to false alarm sources over triple ir detectors. Ir infrared flame detection sensor module detect fire flame. Uvir flame detection model fv20 the dual spectrum uvir technology employs a solar blind uv sensor, with a high signal to noise ratio and a narrow band ir sensor. All views in the main 3d window can be exported to images files, or. All units feature heated sensor windows to eliminate condensation and. The cost and weight saving powerloop concept is a twowire power and signalling bus running from the autrosafe integrated fire and gas ifg panel to the detectors in a ring topology galvanically isolated from the rest of the system. Notifier by honeywell has been manufacturing and supplying fire detection. The ir3 flame detector is sensitive to low frequency, flickering infrared radiation emitted by flames during combustion.

Crowcon offers a range of infrared ir and ultraviolet uv based flame detectors for quickly detecting flames at a distance. When installed properly, can supervise the pilot flame and. The range consists of uv, uvir and ir3 flame detectors. Flame detector testers flame detector testers are designed to test flame detectors with various detecting principles and different mounting positions in maritime, offshore and industrial applications. Phoenix triple ir flame detector bcr002000030 product data sheet june 2012 pms uncoated pms coated cmyk grey black pms cmyk greyscale black very serious risks to human life, productivity and equipment are always present. An array of 256 infrared sensors plus two optical channels view the protected area. The model fl3111 is an ultraviolet uv flame detector. The salwico flame detectors are designed to be used in heavy duty applications in the maritime industry. Fire detection and alarm systems nbs national bim library. The 3 channel flame detector fmx5000 ir evaluates the ir range of the optical spectrum. All utilize sophisticated sensing and signal analysis to detect fires quickly while also rejecting false alarms. It responds to the light emitted from flames during combustion.

Detects a flame or a light source of a wavelength in the range of 760nm1100 nm. Fire detection and alarm systems consist of control and indicating equipment, detection devices, manual call points, and visual audible alarms. A1 general the pyrotector model 302056b ir flame detector is a compact, unitized package containing an ir detection cell, solid state electronics and dry formc spdt contacts for alarm and fault conditions. Fire alarm systems 016589 flame detector, ir3 016589 flame detector, ir3.

A guide to flame detector selection in recent years dual spectral detection was considered the most advanced method to cope with false alarms. Since it responds to flickering radiation the ir3 flame detector can operate even if the. It is therefore essential that flame detectors discriminate between actual flames and radiation from sunlight, lightning, arc welding, hot objects, and other non flame sources. Ipesir3 flame detector 8200003 operating manual page 8 of 32. Flamevision can be trusted in high dependency situations where fast acting and accurate flame detection is essential. Flame detection for silane and other nonhydrocarbon fires. The general monitors model fl3110 is an ultravioletinfrared uvir flame detector. White paper the experts in flame and gas detection. Detection principle detection of low frequency 1 to 15 hz flickering infrared radiation operating wavelength band 0.

There are many different types of flame detectors available in the market today. Ipesir3 flame detector operating manual esp safety inc. Defining the requirements for an application is also essential, as such factors as the type of fuel, minimum fire size to be detected, and the configuration of the space to be monitored can influence the choice of instrument. This unique flame analysis capability patent pending has been incorporated into the triple ir fire detector manufactured by spectrex, inc. Ir3 flame detectors advanced microprocessor based technology ensures rapid flame recognition and alarm signaling. The fsl100 may be small and lightweight for easy installation but it is designed to work in tough indooroutdoor environments, as well as potentially explosive atmospheres. The detector discriminates between flames and other light sources by responding only to particular optical wavelengths and flame flicker frequencies. Since it responds to flickering radiation the ir3 flame detector can operate even if the lens is contaminated by a layer of oil, dust watervapour or ice.

56 404 293 802 1074 651 223 829 1174 607 1022 851 1310 11 1253 1437 1287 1063 124 681 134 742 826 238 155 587 181 647 1524 1377 1333 250 1210 1306 18 1491 489 1106 183 1224 763